Other information:
Specifications
Damper Clutch Control VFS
? Control type : Normal low type
Control Pressure kpa (kgf/cm?, psi)0~500.14 (0~5.1,0~72.54)Current value(mA)0~850 Internal resistance(?)4.8~5.4
...
Removal
1.
Disconnect the battery negative cable, and wait for at least three minutes before beginning work.
2.
Remove the front anchor seat belt (A).
? Anchor seat belt separation method
1) Expose the red colored indicator pin (A) by pushing the slot hole using a O ...