Hyundai Genesis: Automatic Transmission Control System / Damper Clutch Control Solenoid Valve Description and Operation
Damper Clutch control solenoid valve is attached to the valve
body. This variable force solenoid valve directly controls the
hydraulic pressure inside the Damper Clutch.

Inspection
1.
Turn ignition switch OFF.
2.
Disconnect the E Module connector.
3.
Measure resistance between solenoid valve terminals.
4.
Check that the resistance is within the spec ...
Specifications
Damper Clutch Control VFS
? Control type : Normal low type
Control Pressure kpa (kgf/cm?, psi)0~500.14 (0~5.1,0~72.54)Current value(mA)0~850 Internal resistance( ...
Other information:
System Diagram
1. PGS Unit2. AVN monitor (LCD)3. Rear view camera
...
Components
1. Shift lever knob2. Shift lever boots3. Shift lever assembly4. Shift cable
...